fbpx

Arctic

indirect evaporative coolers
indirect evaporative coolers
indirect evaporative coolers
indirect evaporative coolers
IDEC-1
IDEC-2
IDEC-3
IDEC-4
previous arrowprevious arrow
next arrownext arrow
idec-1
idec-2
idec-3
idec-4
previous arrow
next arrow

InDirect Evaporative Coolers

Indirect Cooling

A single stage Indirect Evaporative Coolers use the advantages of cooling using water evaporation without increasing humidity in the supply air. This is done through our special DRI COOL module.

 

A 2-stage evaporative cooling system is an advanced cooling system that utilizes indirect evaporative cooling modules followed by a direct cooling section. The overall result is lower dry bulb temperature as compared to a direct only evaporative coolers.

 

A third stage can be added as a cooling coil which is turned on when the second direct evaporative cooling section is off. This is based on the ambient conditions.

 

These units are also offered in very large air volumes and with all sensors, controls and electrical packaged on board the unit.

Features

indirect evaporative coolers

Double skin casing – outer casing made of pre-coated sheets

indirect evaporative coolers

High efficiency centrifugal fans

indirect evaporative coolers

High Efficiency (90%+) long life evaporative EcoCool pads

indirect evaporative coolers

No harmful refrigerants or ozone depleting chemicals

indirect evaporative coolers

AHRI Certified casing for Leakage

indirect evaporative coolers

Fully factory manufactured and tested units

indirect evaporative coolers

Ready to use , plug & play

indirect evaporative coolers

Pre Coated Galvanised Steel

indirect evaporative coolers

Centrifugal

Benefits

indirect evaporative coolers

Consumes up to 80% less electricity compared to conventional air-conditioning

indirect evaporative coolers

Offers significantly cooler air & with minimal moisture addition

indirect evaporative coolers

Requires smaller duct & less fan power to achieve same cooling

indirect evaporative coolers

Lower Indoor temperature & higher comfort compared to conventional cooling methods

indirect evaporative coolers

Environment and wallet friendly

indirect evaporative coolers

The hotter & drier the air , the greater is the cooling

indirect evaporative coolers

Best Possible Indoor Air Quality

Ideal for

Stay cool and comfortable in any industry or environment with Arctic Coolers - the efficient and cost-effective cooling solution for large industrial facilities, commercial spaces, manufacturing plants, stadium seating areas, distribution Centers of FMCGs, and Warehouses. Improve employee productivity, enhance customer experiences, and maintain consistent temperatures with arctic coolers, the innovative alternative to traditional air conditioning.

Large Industrial

Commercial Spaces

Manufacturing Industry
Warehouses
Indoor Stadiums
Training Areas
Stadium Seating Areas
Distribution Centers of FMCGs

Ideal for

There are many variations of passages of Lorem ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words.

indirect evaporative coolers
  • Large Industrial & Commercial Spaces
  • Manufacturing Industry
  • Warehouses
  • Indoor Stadiums
  • Training Areas
  • Stadium Seating Areas
  • Distribution Centers of FMCGs

Range of Products

indirect evaporative coolers
... ID-L3-30
... ID-L3-50
... ID-L3-75
... ID-L3-100
Minimum Evaporation Efficiency 80% 80% 80% 80%
POD Surface Area 1.35 m2 1.35 m2 1.35 m2 1.35 m2
POD Thickness 75 mm 75 mm 75 mm 75 mm
Connectin Load 0.79KW 0.79KW 0.79KW 0.79KW
Overall Dimensions( L x w x H) 950 x 950 x 800(mm) 950 x 950 x 800(mm) 950 x 950 x 800(mm) 950 x 950 x 800(mm)
Connection Size 400 x 400 mm 400 x 400 mm 400 x 400 mm 400 x 400 mm
Tank Capacity 60 Liters 60 Liters 60 Liters 60 Liters
Dry Weight 125 Kgs 125 Kgs 125 Kgs 125 Kgs
Design Guide- SI Units
Air Flow at Given ESP 8000 m3/h 8000 m3/h 8000 m3/h 8000 m3/h
Static Pressure 19 mmWc 19 mmWc 19 mmWc 19 mmWc
External Static Pressure 5 mmWc 5 mmWc 5 mmWc 5 mmWc
Air Flow at Below ESP 5100 m3/h 5100 m3/h 5100 m3/h 5100 m3/h
Static Pressure 22.5 mmWc 22.5 mmWc 22.5 mmWc 22.5 mmWc
Extenal Static Pressure 10 mmWc 10 mmWc 10 mmWc 10 mmWc

Technical Data

Model ID-L3-30 ID-L3-50 ID-L3-75 ID-L3-100 ID-L3-150 ID-L3-200 ID-L3-250 ID-L3-300 ID-L3-350 ID-L3-400
Air Flow Capacity CMH 5098 8500 12700 17000 25500 34000 42500 50977 59500 68000
CFM 3000 5000 7500 10000 15000 20000 25000 30000 35000 40000
Supply Air Motor KW 2.2 3.7 5.5 7.5 9.3 15 18.5 18.5 22 15 X 2
Working Air Motor KW 0.75 1.1 1.1 1.5 2.2 3.7 3.7 5.5 3.7 X 2 3.7 X 2
Pump kw 0.19 0.25 x 2 0.25 x 2 0.25 x 2 0.25 x 2 0.25 x 2 0.25 x 2 0.25 x 2 0.25 x 2 0.25 x 2
ESP (pa) 250 250 250 250 250 250 250 250 250 250
Overall Dimensions (L x W x H) Length 2440 2890 2890 3350 3625 3775 3925 4075 4075 3775
Width 1350 1555 2100 2710 2400 2710 3270 3765 4360 4970
Height 1850 1850 1850 1850 2950 2950 3050 3100 3200 3200
H1 600 750 750 860 1045 1045 1150 1390 1045 1045
Unit Weight 690 1070 1450 1670 2250 2640 3050 3500 3930 4210
Appr. Perating Weight 860 1240 1620 1840 2420 2810 3220 3670 4100 4380
whatsapp_avatar

ARCTIC Support
Online

For assistance, please enter your email and phone number below.
×
Chat with Us